Back to the septic review queue

Septic maintenance (pump-out): 1548 Sycamore Dr

Approved

Filed Aug 22, 2020 by Riley Calloway, Heritage Pumping Co. Filed from a phone.

Report

Date of service
Aug 22, 2020
Tank size
1500 gal
Compartments
1
Parts this system has
Septic tank, Drainfield or mound
Gallons pumped
1345 gal
Sludge depth
30 in
Scum depth
5 in
Baffles in good condition
No
Effluent filter
Replaced
Lids and risers secure
Yes
Drainfield or mound: no surfacing, soggy ground or odor
Yes
Disposal site
Permitted land-application site
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Riley Calloway, current on the service date
  • All required fields present
  • Address matches parcel 057-56-01060
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

1548 Sycamore Dr
Owner: Rowan Kessler
Parcel 057-56-01060