Back to the septic review queue

Septic maintenance (pump-out): 9816 Ridgeview Way

Approved

Filed Jul 8, 2019 by Shawn Wexler, Clearwater Septic Service. Filed from a phone.

Report

Date of service
Jul 8, 2019
Tank size
750 gal
Compartments
2
Parts this system has
Septic tank, Distribution box, Drainfield or mound
Gallons pumped
782 gal
Sludge depth
29 in
Scum depth
7 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
Yes
Distribution box level, clear and undamaged
No
Drainfield or mound: no surfacing, soggy ground or odor
No
Disposal site
Permitted land-application site
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Shawn Wexler, current on the service date
  • All required fields present
  • Address matches parcel 057-33-01028
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Distribution box reported uneven, blocked or damaged.
  • Surfacing, soggy ground or odor at the drainfield or mound.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

9816 Ridgeview Way
Owner: Reese Danner
Parcel 057-33-01028