Septic maintenance (pump-out): 3226 Hickory Ln

Approved

Filed Dec 17, 2020 by Sam Ashby, Heritage Wastewater. Filed from a phone.

Report

Date of service
Dec 17, 2020
Tank size
1500 gal
Compartments
2
Parts this system has
Septic tank, Drainfield or mound
Gallons pumped
1531 gal
Sludge depth
25 in
Scum depth
9 in
Baffles in good condition
No
Effluent filter
None present
Lids and risers secure
Yes
Drainfield or mound: no surfacing, soggy ground or odor
Yes
Disposal site
Regional wastewater plant
Repair needed
No
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Sam Ashby, current on the service date
  • All required fields present
  • Address matches parcel 053-29-01124
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • No photos attached.
  • Result: passing. Next due date resets when approved.

Decision

Approved by J. Staff. The property's next due date is set and the owner gets a receipt.

Property

3226 Hickory Ln
Owner: Morgan Wexler
Parcel 053-29-01124