Septic maintenance (pump-out): 1206 Stone Gate Ct

Approved

Filed Dec 1, 2020 by Reese Okafor, Summit Wastewater. Filed from a phone.

Report

Date of service
Dec 1, 2020
Tank size
1000 gal
Compartments
1
Parts this system has
Septic tank, Pump tank and effluent pump, High-water alarm, Drainfield or mound
Gallons pumped
1044 gal
Sludge depth
34 in
Scum depth
2 in
Baffles in good condition
No
Effluent filter
Replaced
Lids and risers secure
Yes
Pump runs and the floats turn it on and off
Yes
Alarm tested and working
Yes
Drainfield or mound: no surfacing, soggy ground or odor
No
Disposal site
Permitted land-application site
Repair needed
Yes
Repair needed: describe
Distribution box settled
Photos
2 attached
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Reese Okafor, current on the service date
  • All required fields present
  • Address matches parcel 051-49-01111
  • Sludge is over a third of a typical tank depth; check for system failure.
  • Baffles reported damaged; county may require repair.
  • Surfacing, soggy ground or odor at the drainfield or mound.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

1206 Stone Gate Ct
Owner: Sam Okafor
Parcel 051-49-01111