Back to the septic review queue

Septic maintenance (pump-out): 5766 Sycamore Trl

Approved

Filed Nov 3, 2024 by Jamie Ramirez, Keystone Septic Service. Filed from a phone.

Report

Date of service
Nov 3, 2024
Tank size
1250 gal
Compartments
1
Parts this system has
Septic tank, Drainfield or mound
Gallons pumped
1151 gal
Sludge depth
25 in
Scum depth
6 in
Baffles in good condition
Yes
Effluent filter
Replaced
Lids and risers secure
Yes
Drainfield or mound: no surfacing, soggy ground or odor
Yes
Disposal site
Regional wastewater plant
Repair needed
Yes
Repair needed: describe
Cracked lid
Photos
None
I certify this report is true and that I performed or supervised the work
Yes

Automatic checks

  • License on file for Jamie Ramirez, current on the service date
  • All required fields present
  • Address matches parcel 041-84-01069
  • Sludge is over a third of a typical tank depth; check for system failure.
  • No photos attached.
  • Result: needs follow-up. The property stays on the overdue list until a passing report arrives.

Decision

Approved by M. Reviewer. The property's next due date is set and the owner gets a receipt.

Property

5766 Sycamore Trl
Owner: Casey Whitcomb
Parcel 041-84-01069