Back to the septic review queue
Septic maintenance (pump-out): 5904 Orchard Trl
ApprovedFiled Dec 3, 2020 by Quinn Okafor, Summit Pumping Co. Filed from a phone.
Report
- Date of service
- Dec 3, 2020
- Tank size
- 1250 gal
- Compartments
- 2
- Parts this system has
- Septic tank, Distribution box, Drainfield or mound
- Gallons pumped
- 1203 gal
- Sludge depth
- 29 in
- Scum depth
- 4 in
- Baffles in good condition
- No
- Effluent filter
- Replaced
- Lids and risers secure
- Yes
- Distribution box level, clear and undamaged
- Yes
- Drainfield or mound: no surfacing, soggy ground or odor
- Yes
- Disposal site
- Regional wastewater plant
- Repair needed
- Yes
- Repair needed: describe
- Outlet baffle missing
- Photos
- None
- I certify this report is true and that I performed or supervised the work
- Yes
Automatic checks
- License on file for Quinn Okafor, current on the service date
- All required fields present
- Address matches parcel 007-23-01320
- Sludge is over a third of a typical tank depth; check for system failure.
- Baffles reported damaged; county may require repair.
- No photos attached.
- Result: needs follow-up. The property stays on the overdue list until a passing report arrives.
Decision
Approved by J. Staff. The property's next due date is set and the owner gets a receipt.
Property
5904 Orchard Trl
Owner: Logan Calloway
Parcel 007-23-01320